Thermal imaging explained in new NHBC Foundation guide

Housing Thu, Jan 30, 2020 3:52 PM

In a typical existing British home, up to one third of the heat produced by the heating system can be lost through the roof, ceiling and walls.

When carried out properly a thermographic survey can help identify for gaps in insulation.

The NHBC Foundation in collaboration with BSRIA has published a brand-new guide for this increasingly useful technology. It identifies what a good thermographic survey should include, gives examples of typical thermal imagery and highlights what makes a successful report.

New homes built to the latest building regulations will typically hold their heat more efficiently thanks to improvements in modern insulation and double glazing. But with higher expectation from today’s potential buyers - many are looking for ‘greener’ homes; now more than ever builders need to demonstrate the carbon footprint of their new properties.

Thermal imaging has been used for some time to give a non-invasive ‘window’ at various stages of construction. It can show the thermal performance of the external walls, roofs and internal services. The Thermal imaging report guide, available free of charge from today, gives advice on good practice and highlights the most common issues that can affect the accuracy of a thermal imaging report if the survey isn’t interpreted correctly including:

  • Use the correct equipment - a specialist thermal camera detects infrared radiation which is electromagnetic radiation (EMR) with longer wavelengths than those of visible light and therefore, generally invisible to the human eye. The correct settings of this specialist camera are crucial for an accurate survey.
  • Use a qualified person – a thermographer - the interpretation of a report is key, it is recommended that the person carrying out a thermal imaging survey is suitably qualified, these experts are referred to as thermographers.
  • Suitable weather conditions at the time of the survey are vital in achieving an accurate picture of the thermal performance and, ideally, there should be no significant changes in external temperature during the 24 hours before the survey, nor should it be raining or windy during the survey. Additionally, the survey should only be conducted when there is an adequate temperature difference between inside and outside of the property.

Richard Smith, Head of Standards, Innovation & Research at NHBC, said: "The information provided by a thermal imaging report can be extremely valuable in identifying heat ‘leaks’ if they exist, that may not have been easily detected. With that extra information builders and customer care personnel can reassure homebuyers that their new homes will indeed save energy and money.

“But it’s worth noting the importance of using a qualified person, with the correct equipment and in the right environment. Having these elements in place are beneficial to achieving accurate and useful results. For anyone involved in the construction of new homes, the NHBC Foundation’s latest guide will also highlight how an accurate thermal imaging survey can distinguish between good construction and a potential fault.”

Featured News

Specification news
Flooring That Helps Homes Reduce Environmental Impact

Beauflor® provides cost-effective and durable sheet vinyl flooring for social and...

Read More >>

Specification news
Saniflo launches Clear Water pump range

Saniflo is pleased to announce the launch of the brand new Clear Water range — a...

Read More >>

BUILDING PRODUCT LIBRARY - LATEST BROCHURES

Your Specialist Partner in Composite Steel Roof & Floor Decking Brochure

Your Specialist Part...
By RMD Profiles Ltd

Download Now >>

PVC-U System Fully Reversible Windows by Epwin Window Systems Brochure

PVC-U System Fully R...
By Epwin window systems...

Download Now >>

Spectus Bevelled Windows and Doors Brochure

Spectus Bevelled Win...
By Epwin window systems...

Download Now >>

Vertical Sliding Sash Window Brochure

Vertical Sliding Sas...
By Epwin window systems...

Download Now >>

Two-Part Cill System Brochure

Two-Part Cill System
By Epwin window systems...

Download Now >>

BUILDING PRODUCT DIRECTORY - LATEST PRODUCTS

DUOFLEX
DUOFLEX

DUOFLEX is a high quality elastomeric bitumen, hot bonded to the substrate incorporating the fleece...

Read More >>

TECSOUND
TECSOUND

TECSOUND is a polymer based, bitumen-free, high-density synthetic membrane. The combination of its...

Read More >>

ISOLAIR MULTI
ISOLAIR MULTI

ISOLAIR MULTI is a natural and ecological vapour-permeable, windproof and water-repellent thermal...

Read More >>

CONSTRUCTION VIDEOS - LATEST VIDEOS

Discover the Power of Blue Roofs in Urban Flood Management
Discover the Power of Blue Roofs in Urban Flood Management

In this video, we explore how blue roofs are transforming urban landscapes by helping to mitigate...

Watch Now >>

RMD Profiles - UK Experts in Metal Decking, Design Installation
RMD Profiles - UK Experts in Metal Decking, Design Installation

At RMD Profiles, we’re more than just metal decking. From supply-only solutions to full design and...

Watch Now >>

A responsible addition: HIMACS shapes are now SCS-Certified for recycled content
A responsible addition: HIMACS shapes are now SCS-Certified for recycled content

HIMACS has long been the solid surface material of choice for architects and designers looking for a...

Watch Now >>